Sierra Pallet Inc.: OSHA inspection records
Data as of November 16, 2026
$30,723initial (proposed) penalties
9 alleged violation items across 2 cited inspections in the last 12 months, including 4 serious.
Status2 final orderinspection status per the public record
Get Nevada alerts- Location
- 400 Western Road, Reno, NV 89506
- Industry
- Manufacturing (NAICS 321920, Other Wood Product Manufacturing)
- Jurisdiction
- Nevada, State plan
- Cited inspections
- 2 in the last 12 months
- Inspection history
- Inspected 9 times since 2010; 8 of those inspections had citations.
Alleged violations. Citations issued by a State Plan office. Citations are allegations with proposed penalties until they become final orders; each record shows its status label, initial and current penalty as of November 16, 2026. About this data · Methodology
Official records: each osha.gov link opens the official record, next to its inspection number. If osha.gov asks you to verify you're human and then shows its homepage, search that number at OSHA's Establishment Search.
Inspection 348601279
Final order The citation items have become a final order.
- Opened
- November 19, 2025
- Citations issued
- April 3, 2026
- Abatement due
- April 13, 2026 to May 8, 2026 (per OSHA record)
- Final order date
- May 6, 2026 (per OSHA record)
- Official record
- osha.gov inspection detail #348601279 · OSHA Establishment Search (if osha.gov shows its homepage, search inspection 348601279)
| Citation | Standard | Type | Issued | Abatement due | Initial penalty | Current penalty | Status |
|---|---|---|---|---|---|---|---|
| Citation 01001 | 1910.219(f)(3) Power Transmission Guarding | Serious | Apr 3, 2026 | May 8, 2026 | $8,276 | $8,276 | Final order |
| Citation 01002 | 1910.219(c)(2)(i) Power Transmission Guarding | Serious | Apr 3, 2026 | May 8, 2026 | $8,276 | $8,276 | Final order |
| Citation 02001 | 1910.303(b)(2) Electrical General | Other-than-serious | Apr 3, 2026 | — | $0 | $0 | Final order |
| Citation 02002 | 1910.157(c)(4) Fire Extinguishers | Other-than-serious | Apr 3, 2026 | Apr 13, 2026 | $0 | $0 | Final order |
| Citation 02003 | 1910.303(b)(7)(iv) Electrical General | Other-than-serious | Apr 3, 2026 | Apr 13, 2026 | $0 | $0 | Final order |
| Citation 02004 | 1910.242(b) Hand & Power Tools | Other-than-serious | Apr 3, 2026 | Apr 23, 2026 | $930 | $930 | Final order |
Inspection 348601337
Final order The citation items have become a final order.
- Opened
- November 19, 2025
- Citations issued
- April 3, 2026
- Abatement due
- May 20, 2026 (per OSHA record)
- Final order date
- May 6, 2026 (per OSHA record)
- Official record
- osha.gov inspection detail #348601337 · OSHA Establishment Search (if osha.gov shows its homepage, search inspection 348601337)
| Citation | Standard | Type | Issued | Abatement due | Initial penalty | Current penalty | Status |
|---|---|---|---|---|---|---|---|
| Citation 01001 | 1910.95(c)(1) Occupational Noise | Serious | Apr 3, 2026 | May 20, 2026 | $8,276 | $8,276 | Final order |
| Citation 01002 | 1910.134(c)(2)(ii) Respiratory Protection | Serious | Apr 3, 2026 | — | $4,965 | $4,965 | Final order |
| Citation 02001 | 1910.134(h)(2)(i) Respiratory Protection | Other-than-serious | Apr 3, 2026 | — | $0 | $0 | Final order |
Inspection history since 2010
OSHA recorded 9 inspections at this establishment name and ZIP code since 2010, the most recent opened Nov 19, 2025. 8 of them had citations. 1 earlier inspection with citations opened in the five years before the most recent one; OSHA's repeat classification generally looks back five years.
Inspections opened per year. Same establishment name and ZIP code in DOL's full inspection history; different spellings or addresses of one business are not joined.
| Inspection | Opened | Alleged items | Initial penalty | Source |
|---|---|---|---|---|
| Inspection 348601279 | Nov 19, 2025 | 6 | $17,482 | osha.gov #348601279 |
| Inspection 348601337 | Nov 19, 2025 | 3 | $13,241 | osha.gov #348601337 |
| Inspection 346049265 | Jun 28, 2022 | 12 | $20,208 | osha.gov #346049265 |
| Inspection 343291290 | Jul 9, 2018 | No citations recorded | — | osha.gov #343291290 |
| Inspection 343283933 | Jul 9, 2018 | 1 | $595 | osha.gov #343283933 |
| Inspection 341318293 | Mar 10, 2016 | 1 | $1,400 | osha.gov #341318293 |
| Inspection 341296978 | Mar 2, 2016 | 5 | $2,100 | osha.gov #341296978 |
| Inspection 314964503 | Oct 26, 2010 | 3 | $3,600 | osha.gov #314964503 |
| Inspection 314816125 | Oct 7, 2010 | 14 | $12,900 | osha.gov #314816125 |
Compared with similar employers
Among 340 other Other Wood Product Manufacturing (NAICS 3219) establishments nationwide with citations issued in the last 12 months, this establishment's proposed penalties ($30,723) were higher than 87% of them, and its 9 alleged items more than 88%.
| Last 12 months | This establishment | Peer median | Higher than |
|---|---|---|---|
| Initial (proposed) penalties | $30,723 | $7,200 | 87% |
| Alleged violation items | 9 | 3 | 88% |
Standards cited most in this industry
Share of the 376 cited inspections in Other Wood Product Manufacturing (NAICS 3219) nationwide (last 12 months) that included each standard; the ones marked were also cited here.
| Standard | Topic | Share of inspections | Cited here |
|---|---|---|---|
| 1910.147 | Lockout/Tagout | 23% | |
| 1910.178 | Forklifts | 16% | |
| 1910.213 | Woodworking Machinery | 15% | |
| 1910.1200 | Hazard Communication | 13% | |
| 1910.212 | Machine Guarding | 13% | |
| 1910.303 | Electrical General | 10% | Yes |
Other manufacturing employers cited in Nevada
- EM Research, Inc.Reno, issued Sep 25, 2026, $25,323 initial (proposed)
- Hoagland Enterprises Reno LLCReno, issued Sep 15, 2026, $5,427 initial (proposed)
- Temperatsure, LLCReno, issued Aug 25, 2026, $49,652 initial (proposed)
- Baystone Inc.Reno, issued Jun 25, 2026, $11,255 initial (proposed)
- Kimmie Candy CompanyReno, issued Apr 22, 2026, $16,551 initial (proposed)
- True Fab & Powder, LLCReno, issued Jul 24, 2026, $3,368 initial (proposed)
Related
- Nevada OSHA citations
- Nevada manufacturing citations
- 1910.303 Electrical General
- 1910.134 Respiratory Protection
- 1910.157 Fire Extinguishers
- 1910.219 Power Transmission Guarding
- 1910.242 Hand & Power Tools
- 1910.95 Occupational Noise
Is something on this page wrong or out of date? Request a correction or removal.