1926.350 Gas Welding and Cutting: citations, penalties and recently cited employers
Data as of October 5, 2026 · citations issued Oct 5, 2025 to Oct 5, 2026
This section governs the transport, storage, and use of compressed gas cylinders and equipment for oxy-fuel welding and cutting in construction. Cylinders must have valve protection caps in place when not connected, be secured upright, and be kept away from heat sources. Oxygen cylinders in storage must be separated from fuel-gas cylinders and combustibles by distance or a fire-resistant barrier, and hoses, torches, and regulators must be in good condition.
What the standard requires
- Keep valve protection caps on cylinders not in use
- Secure cylinders upright to prevent tipping
- Separate stored oxygen from fuel gas by 20 feet or a fire-resistant barrier
- Inspect hoses, torches, and regulators for leaks and damage
Hazards it addresses
- Fires and explosions from gas leaks
- Cylinder rupture or valve breakage
- Burns during cutting operations
Cited in steel erection, pipefitting, demolition, and mechanical contracting.
Plain-language summary written for this site; it is not the regulatory text and not legal advice. Read the official text at eCFR.
Citations by month
Inspections with citations issued, by month of issuance. Hatched months are incomplete: citations reach the public data about a month after issuance.
Most-cited paragraphs
| Paragraph | What it covers | Items | Inspections | Median initial penalty |
|---|---|---|---|---|
| 1926.350(a)(10) | Stored oxygen cylinders must be separated from fuel-gas cylinders or combustibles by at least 20 feet or a 5-foot-high barrier with a half-hour fire rating. | 12 | 12 | $300 |
| 1926.350(a)(9) | Compressed gas cylinders must be secured in an upright position at all times except when being hoisted or carried. | 5 | 5 | $0 |
| 1926.350(a)(11) | 3 | 3 | $525 | |
| 1926.350(a)(12) | 2 | 2 | $2,128 | |
| 1926.350(a)(4) | 1 | 1 | $600 |
Penalties
Across 23 alleged items, OSHA and state-plan offices proposed $37,139 in initial penalties. The current total in the public data is $31,630, 15% lower after settlements, contests and amendments.
By violation type: Serious 57%; Other-than-serious 43%.
Citations by state
| State | Inspections cited | Items | Initial penalties | Current penalties |
|---|---|---|---|---|
| Maryland | 3 | 3 | $2,550 | $2,400 |
| Alabama | 2 | 4 | $0 | $0 |
| Virginia | 2 | 3 | $600 | $420 |
| Vermont | 2 | 3 | $8,157 | $5,402 |
| Alaska | 1 | 1 | $3,826 | $2,678 |
| New Jersey | 1 | 1 | $11,585 | $11,585 |
| Nevada | 1 | 1 | $0 | $0 |
| New York | 1 | 1 | $0 | $0 |
| Pennsylvania | 1 | 2 | $4,965 | $4,965 |
| Puerto Rico | 1 | 1 | $0 | $0 |
| Tennessee | 1 | 2 | $1,200 | $1,200 |
| Washington | 1 | 1 | $4,256 | $2,979 |
By industry
- Construction: 15 inspections
- Manufacturing: 1 inspections
- Public administration: 1 inspections
Recently cited establishments
About these records. Citations list alleged violations and proposed penalties. Employers can contest them, and many are reduced or withdrawn in settlement. Each row shows the original and the current penalty and a status label derived from the public data as of October 5, 2026. Check the linked osha.gov page for the official record.
| Establishment | Location | Issued | Alleged items | Initial penalty | Current penalty | Status and deadlines | Source |
|---|---|---|---|---|---|---|---|
| Western Marine Construction | Ketchikan, AK | Aug 28, 2026 | 1 | $3,826 | $2,678 | Informal settlement | osha.gov |
| D&D Wood Sales, Inc. | Roaring Spring, PA | Aug 7, 2026 | 2 | $4,965 | $4,965 | Final orderAbatement due Sep 2, 2026 | osha.gov |
| Olean City Public Works Department | Olean, NY | Jul 1, 2026 | 1 | $0 | $0 | Final orderAbatement due Jul 14, 2026 | osha.gov |
| Wildwood Hospitality Group LLC | Wildwood, NJ | Jun 26, 2026 | 1 | $11,585 | $11,585 | ContestedAbatement due Jul 2, 2026Contested Jul 17, 2026 | osha.gov |
| Bradley Plumbing & Heating, Incorporated | Montgomery, AL | Jun 15, 2026 | 2 | $0 | $0 | Final order | osha.gov |
| Dixie Electric Company | Montgomery, AL | Jun 15, 2026 | 2 | $0 | $0 | Final order | osha.gov |
| S.A. Halac Iron Works, Inc. | Millersville, MD | Apr 29, 2026 | 1 | $1,200 | $1,200 | Informal settlement | osha.gov |
| Bergerson Construction, Inc. | Everett, WA | Mar 30, 2026 | 1 | $4,256 | $2,979 | Informal settlementAbatement due Apr 23, 2026 | osha.gov |
| Appalachian Plumbing & Piping Service, LLC | Abingdon, VA | Jan 29, 2026 | 1 | $600 | $420 | Informal settlement | osha.gov |
| Razorback LLC | White River Junction, VT | Jan 27, 2026 | 1 | $6,620 | $4,634 | Formal settlementAbatement due Feb 2, 2026Contested Feb 27, 2026 | osha.gov |
| Smiley's Heating and Cooling | Virginia Beach, VA | Dec 18, 2025 | 2 | $0 | $0 | Informal settlementAbatement due Feb 6, 2026 | osha.gov |
| Truckee Meadows Construction, Inc. | Sparks, NV | Dec 5, 2025 | 1 | $0 | $0 | Informal settlement | osha.gov |
| Windham, Town of | Windham, VT | Nov 12, 2025 | 2 | $1,537 | $768 | Informal settlement | osha.gov |
| Denver-Elek, Inc. | Reisterstown, MD | Oct 21, 2025 | 1 | $825 | $825 | Final order | osha.gov |
| Hess Construction Company, LLC | Reisterstown, MD | Oct 21, 2025 | 1 | $525 | $375 | Informal settlement | osha.gov |
| Vhanda WH LLC | Mayaguez, PR | Oct 8, 2025 | 1 | $0 | $0 | ContestedAbatement due Oct 14, 2025Contested Oct 28, 2025 | osha.gov |
| Onsite Emergency Services, LLC | Chattanooga, TN | Oct 24, 2025 | 2 | $1,200 | $1,200 | Final orderAbatement due Aug 11, 2025 | osha.gov |
Often cited together
- 1926.150 Construction Fire Protection (4 shared inspections)
- 1926.251 Rigging Equipment (2 shared inspections)
- 1926.850 Demolition Preparation (2 shared inspections)
- 1926.501 Fall Protection (2 shared inspections)
- 1926.405 Temporary Wiring and Cords (1 shared inspections)
- 1926.701 Concrete and Masonry Work (1 shared inspections)
- 1926.652 Trench Cave-In Protection (1 shared inspections)
- 1926.102 Eye and Face Protection (1 shared inspections)
Questions
What does OSHA standard 1926.350 require?
This section governs the transport, storage, and use of compressed gas cylinders and equipment for oxy-fuel welding and cutting in construction. Cylinders must have valve protection caps in place when not connected, be secured upright, and be kept away from heat sources. Oxygen cylinders in storage must be separated from fuel-gas cylinders and combustibles by distance or a fire-resistant barrier, and hoses, torches, and regulators must be in good condition.
How often was 1926.350 cited in the last 12 months?
In the public data as of October 5, 2026, 1926.350 (Gas Welding and Cutting) appeared in 17 inspections with citations issued between Oct 5, 2025 and Oct 5, 2026, covering 23 alleged violation items.
Which part of 1926.350 is cited most?
1926.350(a)(10) was the most-cited paragraph, with 12 items: Stored oxygen cylinders must be separated from fuel-gas cylinders or combustibles by at least 20 feet or a 5-foot-high barrier with a half-hour fire rating.
Which states cite 1926.350 most often?
The most citations under 1926.350 in this period were issued in Maryland, Alabama, Virginia.
What is the typical penalty for a 1926.350 violation?
The median initial (proposed) penalty per item was $525; the median current penalty after settlements and amendments was $375. Totals: $37,139 proposed, $31,630 current. Penalties vary by violation type, employer size and history, and State Plans set their own amounts.
Are 1926.350 citations final?
Not necessarily. A citation is an allegation until it becomes a final order. 13% of these items were contested, and many others were changed in settlements. Each listing shows its current status and a link to the official record.