Integrated Construction, LLC: OSHA inspection records
Data as of November 16, 2026
$8,490initial (proposed) penalties
2 alleged violation items across 1 cited inspection in the last 12 months, including 2 serious.
Status1 final orderinspection status per the public record
Get Virginia alerts- Location
- 525 South Pollard Street, Vinton, VA 24179
- Industry
- Construction (NAICS 236220, Nonresidential Building Construction)
- Jurisdiction
- Virginia, State plan
- Cited inspections
- 1 in the last 12 months
Alleged violations. Citations issued by a State Plan office. Citations are allegations with proposed penalties until they become final orders; each record shows its status label, initial and current penalty as of November 16, 2026. About this data · Methodology
Official records: each osha.gov link opens the official record, next to its inspection number. If osha.gov asks you to verify you're human and then shows its homepage, search that number at OSHA's Establishment Search.
Inspection 348739962
Final order The citation items have become a final order.
- Opened
- February 11, 2026
- Citations issued
- April 6, 2026
- Abatement due
- April 30, 2026 (per OSHA record)
- Final order date
- May 5, 2026 (per OSHA record)
- Official record
- osha.gov inspection detail #348739962 · OSHA Establishment Search (if osha.gov shows its homepage, search inspection 348739962)
| Citation | Standard | Type | Issued | Abatement due | Initial penalty | Current penalty | Status |
|---|---|---|---|---|---|---|---|
| Citation 01001 | 1926.501(b)(10) Fall Protection | Serious | Apr 6, 2026 | Apr 30, 2026 | $4,820 | $4,820 | Final order |
| Citation 01002 | 1926.501(b)(4)(ii) Fall Protection | Serious | Apr 6, 2026 | Apr 30, 2026 | $3,670 | $3,670 | Final order |
Compared with similar employers
Among 97 other Nonresidential Building Construction (NAICS 2362) establishments in Virginia with citations issued in the last 12 months, this establishment's proposed penalties ($8,490) were higher than 62% of them, and its 2 alleged items more than 33%.
| Last 12 months | This establishment | Peer median | Higher than |
|---|---|---|---|
| Initial (proposed) penalties | $8,490 | $5,718 | 62% |
| Alleged violation items | 2 | 2 | 33% |
Standards cited most in this industry
Share of the 1,126 cited inspections in Nonresidential Building Construction (NAICS 2362) nationwide (last 12 months) that included each standard; the ones marked were also cited here.
| Standard | Topic | Share of inspections | Cited here |
|---|---|---|---|
| 1926.501 | Fall Protection | 22% | Yes |
| 1926.451 | Scaffold Safety | 8% | |
| 1926.1053 | Ladder Safety | 6% | |
| 1926.503 | Fall Protection Training | 4% | |
| 1926.502 | Fall Protection Systems | 4% | |
| 1926.453 | Aerial Lifts | 4% |
Other construction employers cited in Virginia
- White Electrical Services LLCVinton, issued Jul 29, 2026, $2,095 initial (proposed)
- Burton Construction Co., Inc., J. ESouth Boston, issued Oct 7, 2026, $705 initial (proposed)
- Harman Construction, Inc.Bridgewater, issued Sep 30, 2026, $21,285 initial (proposed)
- Meza Framing LLCRocky Mount, issued Sep 15, 2026, $48,855 initial (proposed)
- Thomas Builders of Virginia, Inc.Waynesboro, issued Sep 14, 2026, $170,319 initial (proposed)
- Dci/Shires, Inc.Blacksburg, issued Sep 11, 2026, $3,440 initial (proposed)
Related