Citation Atlas

Dvorak, LLC: OSHA inspection records

Data as of November 16, 2026

$10,000initial (proposed) penalties

3 alleged violation items across 1 cited inspection in the last 12 months, including 3 serious.

Status1 contestedinspection status per the public record

Get Maryland alerts
Location
3501 Asiatic Ave., Baltimore, MD 21226
Industry
Construction (NAICS 238210, Building Equipment Contractors)
Jurisdiction
Maryland, State plan
Cited inspections
1 in the last 12 months

Alleged violations. Citations issued by a State Plan office. Citations are allegations with proposed penalties until they become final orders; each record shows its status label, initial and current penalty as of November 16, 2026. About this data · Methodology

Official records: each osha.gov link opens the official record, next to its inspection number. If osha.gov asks you to verify you're human and then shows its homepage, search that number at OSHA's Establishment Search.

Inspection 348986613

Contested Under contest; not a final finding. Items and penalties may change.

$10,000Initial (proposed) penalty
$10,000Current penalty
3Alleged violation items
Opened
June 9, 2026
Citations issued
September 8, 2026
Abatement due
September 16, 2026 (per OSHA record)
Contest date
September 15, 2026 (per OSHA record)
Official record
osha.gov inspection detail #348986613 · OSHA Establishment Search (if osha.gov shows its homepage, search inspection 348986613)
CitationStandardTypeIssuedAbatement dueInitial penaltyCurrent penaltyStatus
Citation 010011926.416(a)(1)
Electrical Work Practices
SeriousSep 8, 2026Sep 16, 2026$4,300$4,300Contested
Citation 010021926.416(a)(3)
Electrical Work Practices
SeriousSep 8, 2026Sep 16, 2026$4,300$4,300Contested
Citation 010031926.960(g)(5)
Energized Power Line Work
SeriousSep 8, 2026Sep 16, 2026$1,400$1,400Contested

Compared with similar employers

Among 59 other Building Equipment Contractors (NAICS 2382) establishments in Maryland with citations issued in the last 12 months, this establishment's proposed penalties ($10,000) were higher than 98% of them, and its 3 alleged items more than 61%.

Last 12 monthsThis establishmentPeer medianHigher than
Initial (proposed) penalties$10,000$76898%
Alleged violation items3261%
Peers: cited establishments in the same NAICS industry in Maryland. Proposed penalties before any settlement.

Standards cited most in this industry

Share of the 1,195 cited inspections in Building Equipment Contractors (NAICS 2382) nationwide (last 12 months) that included each standard.

StandardTopicShare of inspectionsCited here
1926.501Fall Protection16%
1926.1053Ladder Safety7%
1926.652Trench Cave-In Protection5%
1926.503Fall Protection Training5%
1926.405Temporary Wiring and Cords4%
1926.651Excavation Safety4%

Other construction employers cited in Maryland

Related

Is something on this page wrong or out of date? Request a correction or removal.